Vertical
axis wind turbine:
"Iasos I". |
Nominal
power: 1 KVA |
Download |
|||
Power
data and charts. |
Actual electricity
produced "Iasos I" |
Out
of limit |
|||||||||||||
Wind:
m/s |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Per
hour: Wh |
13,2 |
49,8 |
105,7 |
177,9 |
263,3 |
358,9 |
460,6 |
559,2 |
682,2 |
781,8 |
919,0 |
1.043,1 |
1.171,2 |
1.298,3 |
Per
day: Kwh |
0,3 |
1,2 |
2,5 |
4,3 |
6,3 |
8,6 |
11,1 |
13,4 |
16,4 |
18,8 |
22,0 |
25,0 |
28,1 |
31,2 |
Per
month: Kwh |
9,7 |
36,4 |
77,2 |
129,9 |
192,2 |
262,0 |
336,2 |
408,2 |
498,0 |
570,7 |
670,9 |
761,5 |
855,0 |
947,8 |
Per
year: Kwh |
115,8 |
436,4 |
926,2 |
1.558,6 |
2.306,7 |
3.143,8 |
4.034,4 |
4.898,3 |
5.976,0 |
6.848,7 |
8.051,0 |
9.137,6 |
10.259,7 |
11.373,0 |
Average rotational speed of the turbine, under the specified conditions: |
||||||||||||||
rpm |
0,55 |
2,2 |
4,75 |
8,0 |
11,75 |
16,35 |
21,1 |
25,8 |
31,5 |
36,05 |
42,65 |
48,5 |
54,55 |
60,75 |
Nominal turbine torque, with the specific wind speed: |
||||||||||||||
Nm |
3,9 |
15,6 |
36,5 |
64,6 |
100,0 |
143,3 |
195,4 |
256,7 |
327,0 |
405,7 |
491,9 |
585,0 |
685,6 |
796,5 |
Nominal turbine torque, based on wind speed and rotational speed: |
||||||||||||||
Nm |
3,9 |
15,9 |
36,0 |
64,4 |
101,0 |
143,3 |
194,6 |
255,7 |
328,6 |
405,7 |
491,1 |
584,6 |
686,2 |
796,3 |
Actual turbine torque, under the specified conditions: |
||||||||||||||
Nm |
3,4 |
12,5 |
25,4 |
40,9 |
58,3 |
77,1 |
97,4 |
116,7 |
141,3 |
161,3 |
189,1 |
214,3 |
239,9 |
265,6 |
Average rotation speed of the generator, under the specified conditions: |
||||||||||||||
rpm |
3,58 |
14,3 |
30,87 |
52,0 |
77,68 |
106,28 |
137,15 |
167,7 |
204,75 |
234,3 |
177,2 |
315,2 |
354,6 |
394,9 |
Phase voltage of the generator, under the specified conditions: |
||||||||||||||
acv |
1,43 |
5,72 |
12,36 |
20,8 |
31,07 |
42,51 |
54,86 |
67,08 |
81,9 |
93,73 |
110,9 |
126,1 |
141,8 |
157,9 |
Torque supplied by the generator, under the specified conditions: |
||||||||||||||
Nm |
0,38 |
1,52 |
3,28 |
5,52 |
8,25 |
11,28 |
14,56 |
17,8 |
21,74 |
24,88 |
29,43 |
33,47 |
37,64 |
41,92 |
Torque required by the generator, under the specified conditions: |
||||||||||||||
Nm |
0,5 |
1,95 |
4,03 |
6,52 |
9,38 |
12,49 |
15,82 |
19,12 |
23,16 |
26,4 |
31,12 |
35,31 |
39,64 |
44,09 |
Efficiency of the generator, under the specified conditions: |
||||||||||||||
% |
75,4 |
77,9 |
81,3 |
84,7 |
87,9 |
90,3 |
92,0 |
93,1 |
93,9 |
94,2 |
94,6 |
94,8 |
94,96 |
95,08 |
Aerodynamic factor: |
||||||||||||||
% |
5,94 |
10,13 |
12,96 |
14,81 |
16,01 |
16,72 |
17,06 |
17,1 |
17,24 |
17,15 |
17,03 |
16,87 |
16,68 |
16,39 |
Ideal power transmission ratio: |
||||||||||||||
1
× |
1,8 |
2,81 |
3,2 |
4,12 |
4,6 |
5,09 |
5,83 |
6,1 |
6,42 |
6,0 |
7,42 |
7,5 |
7,65 |
8,9 |
Actual power transmission ratio: |
||||||||||||||
1
× |
6,1 |
6,1 |
6,1 |
6,1 |
6,1 |
6,1 |
6,1 |
6,1 |
6,1 |
6,1 |
6,1 |
6,1 |
6,1 |
6,1 |
|