First
Back
Calculate for yourself whether the wind turbine meets your needs.

Chargers controllers for wind turbine: "Iasos".
Charger controller: "H9035"
Input from wind turbine rated power: 3,5 Kw
Input from solars rated power: 1,5 Kw
Applicable to different kinds of batteries.
CHARGER CONTROLLER MPPT FOR WIND GENERATOR, WIND TURBINE THALES, WIND GENERATOR, WIND TURBINE IASOS I, GEAR BOX INGREASER ROTATION SPEED FOR WIND TURBINE, WIND GENERATOR VERTICAL AXIS, wind turbine, wind generator, wind mill, small wind turbine, Household wind turbine, Wind turbine for houses, Wind turbine for hotels, Wind turbine for small factories, Wind power, Green energy, Energy from the wind,
Wind turbine with little wind, Wind turbine with some wind, Vertical axis wind turbines, Vertical axis wind turbine, Coreless generators, Special generators for use in wind turbines, Special generators for hydroelectric use
PWM step-less unload mode, which burn the excess power into dump load,
making the battery charging in best status.

Digital intelligent control, With powerful imported MCU control as the core device. To ensure Simple peripheral circuit Structure, and more flexible and powerful control method and control strategy.

Modular design with simple structure and easy maintenance.
This kind of wind controller is special design for off-grid wind generation system. Appearance is elegant, operations are easy. It also makes the course wind generator charge to batteries safely and efficiently.
Perfect protection function: Battery overcharge protection, Battery over current protection, Battery reverse connection protection, Open battery protection ,Wind turbine automatic brake and manual brake, thus the system has higher reliability.

PARAMETERS, WHEN THE CONTROLLER OPERATES WITH 48 DCV BATTERIES.
Rated wind power:
3,5 Kw
CHARGER CONTROLLER MPPT FOR WIND GENERATOR, WIND TURBINE THALES, WIND GENERATOR, WIND TURBINE IASOS I, GEAR BOX INGREASER ROTATION SPEED FOR WIND TURBINE, WIND GENERATOR VERTICAL AXIS, wind turbine, wind generator, wind mill, small wind turbine, Household wind turbine, Wind turbine for houses, Wind turbine for hotels, Wind turbine for small factories, Wind power, Green energy, Energy from the wind,
Wind turbine with little wind, Wind turbine with some wind, Vertical axis wind turbines, Vertical axis wind turbine, Coreless generators, Special generators for use in wind turbines, Special generators for hydroelectric use

Nominal system voltage:

48 DCV
Battery over-discharge limit voltage (Low):
40.8 V (adjustable)

Battery over-discharge limit recovery voltage (Rlow):

46.5 V (adjustable)
Battery over-charge limit voltage (Full):
58.8 V (adjustable)
Battery over-charge limit recovery voltage (RFull):
52.8 V (adjustable)
Float voltage (Flot):
54.0 V (adjustable)
Wind dumpload rotate speed (Rota):
500 RPM (adjustable)
  It depends on what model generator use.  
Wind pole logarithm (Pole):
10D (adjustable)
  It depends on what model generator use.  
Wind charging range:
DC (25-200) V
Wind start charging voltage (CutIn):
40 ~ 50V (adjustable)
Wind dumpload voltage (Vmax): 200 V (adjustable)
Dump load control mode: Over rotate speed limiting, Over voltage limiting, Over Current limiting, PWM.
Wind charging mode: MPPT (Boost and Buck)
Display mode: LCD
Display content: Battery: Voltage, charging current, Percentage of battery power.
Wind: Voltage, charging current, rotate speed, output current, output power.
System: State, generated energy, error code.
Operating temperature & Relative humidity: - 20 C° ~ +55 C° / 35 ~ 85 % RH (Non-condensing).
Quiescent power drain: < 3 W
Protection type: Battery: Over-discharge protection, over-charge protection, anti-reverse connection, outside switch.
Wind: Over rotate speed protection, over voltage protection, over current protection.
Controller size: 450 mm * 423 mm * 174.43 mm
Package size: 510 mm * 250 mm * 545 mm
Net weight: 15.5 Kg
Gross weight: 17.0 Kg

Important note:
Wherever referred solar, suggests the second input to controller connection, which can be used also for solar connection.
1.
Product Introduction.
1.1
Functions and Features.
1.1.1.
Basic Functions
Wind Turbine and Load Adaptive Impedance Matching, maximize energy utilization.
There is internal resistance in Wind generators, batteries and loads. According to impedance matching principle, only when input impedance equals to output impedance, power utilization is maximal, get the maximum power.
Protect wind generator from over-revolution speed, over-voltage and over-current.
Max revolution speed, max voltage and max current of wind generator could be set. Once the actual revolution speed, voltage or current over the set ones, PWM intelligent unloading will start automatically. That protect wind generator.
Intelligent limiting of batteries max current.
Batteries maximum capacity could be set through this controller. According to the set maximum capacity, controller could calculate the maximum charging current. Then batteries will be protected.
Function of manual brake.
Wind charging manual switch.
On the controller you can manually set whether using wind charge to battery.
BOOST and BUCK function in one.
Once wind generator voltage is lower than battery voltage, controller starts boost module automatically. Wind generator voltage is increased to the charging voltage, and it is boost charging. When wind generator voltage is higher than battery voltage, in order to acquire max power, buck module of controller will be started, the generator is buck charging.
Loads lower the revolution speed of wind generator, when it is breeze. That decreases the output power of wind generator. Through max current tracking (MCT) and max power point tracking (MPPT), output of wind generator is stabilized at the max balance of wind energy utilization. Combine with boost and buck function, wind energy utilization is increased.
RS232 interface.
By serial interface communication, you could monitor the whole system, storage and analyze data.
Program could be upgraded by serial interface.
Connect PC and controller by serial interface. You could set the parameters on PC and controller simultaneously.
Software is free, easy to operate and no need to be installed.
 
1.2.
Design.
CHARGER CONTROLLER MPPT FOR WIND GENERATOR, WIND TURBINE THALES, WIND GENERATOR, WIND TURBINE IASOS I, GEAR BOX INGREASER ROTATION SPEED FOR WIND TURBINE, WIND GENERATOR VERTICAL AXIS, wind turbine, wind generator, wind mill, small wind turbine, Household wind turbine, Wind turbine for houses, Wind turbine for hotels, Wind turbine for small factories, Wind power, Green energy, Energy from the wind,
Wind turbine with little wind, Wind turbine with some wind, Vertical axis wind turbines, Vertical axis wind turbine, Coreless generators, Special generators for use in wind turbines, Special generators for hydroelectric use
   
1.
LCD display panel.
   
A friendly human-computer interaction interface. Running data and configuration parameters are displayed in the LCD screen. Parameters could be set by keys on the panel.
   
2.
Terminal block.
   
Connect wind generator, pv panel, battery and load.
   
3.
Manual brake.
   
4.
Mounting holes.
   
Install controller.
   
5.
Resistance cooling fan and System cooling fan.
   
This fan rotates when wind generator braking ,cooling the resistances.
   
This fan rotates when charging current is too high, cooling the system.
   
6.
Communication interface.
2.
Installation and Electrical Connection.
2.1.
Installation.
2.1.1.
Mounting Notes.
Read through this entire section first before beginning installation.
All mounting work must only be performed by professional personnel.
Disconnect all sources of power to the controller before installing or adjusting.
Do not allow water and snows enter the controller.
Install in locations where is dustless, airy and avoid direct sunlight.
If install controller in a cabinet, make sure there is enough space for controller heat-dissipating.
Keep controller away from corrosive gas and intense electromagnetic interference.
Locate the product in where easy to install, electrical connection and service.
2.1.2.
Mounting Steps.
1.
Choose mounting location.(Please refer to installation notes).
2.
Check for clearance around the location; make sure there is enough space for connecting cables.
3.
Prepare tools for installation.
4.
Place the controller to the mounting location.
5.
Check that the controller is securely mounted.
 
2.2.
Electrical Connection.
   
2.2.1.
Overview of Electrical Connection.
CHARGER CONTROLLER MPPT FOR WIND GENERATOR, WIND TURBINE THALES
Download the diagram
2.2.2.
Wiring Notes.
Improper operation during the wiring process can cause fatal injury to the operator or unrecoverable controller damage. Only qualified personnel can perform the wiring work.
All cables must be undamaged, properly insulated and adequately dimensioned.
Make sure that all cables are firmly attached. Unsecured cables create loose and resistive connections which may lead to excessive heating and /or fire.
For mobile applications, be sure to secure all wiring, avoid loose connections.
2.2.3.
Wiring Steps (Follow the bellow suggestions and steps to connect).
2.2.3.1.
Battery Wiring.
CHARGER CONTROLLER MPPT FOR WIND GENERATOR, WIND TURBINE THALES
Connect battery positive(+) and negative(-) wires to controller as shown in figure 2.2.3.1.
Be careful of avoiding short circuit when wiring the battery.
Before wiring the battery, keep the battery switch of controller (BATTERY) on OFF, Do not switch it to ON untill you confirm the wiring is correct and safe.
Although controller has the protection of battery anti-reverse, but anti-connecting of positive (+) and negative(-) is forbidden.
2.2.3.2.
Wind Generator Wiring .
Connect wind generator wires to controller as shown in figure 2.2.3.1.
The wind generator could produce high voltages. Be careful of electric shock.
When it is breeze or windless, connection of wind generator and controller would be safer and better. Only when controller is in the state of start-up, high-speed rotate wind generator could be connected.
2.2.4.
Confirm Wiring.
Double-check the wiring. Make sure each connection is correct. Secure no loose and resistive connections.
3.
Operation.
3.1.
Description of Buttons.
CHARGER CONTROLLER MPPT FOR WIND GENERATOR, WIND TURBINE THALES
3.2.
Overview of LCD Menu.
CHARGER CONTROLLER MPPT FOR WIND GENERATOR, WIND TURBINE THALES
The gray shaded parameters could be set manually by users.
Parameter setting steps:
1.
Press “Menu” to enter the setting state, setting value would flash.
2.
Press " ” to decrease the setting value. Press “ ” to increase the setting value.
3.
After step 2, press “Menu” to save the setting, press “Esc” to back out.
3.3.
Parameters Browsing.
3.3.1.
Battery.
CHARGER CONTROLLER MPPT FOR WIND GENERATOR, WIND TURBINE THALES
**%— Percentage of battery power
Right corner have below displays:
Low—Battery over-discharge protecting
Normal—Battery is normal
Full—Battery over-charge protecting;
Float—Floating
Ft:**s —Countdown of exiting float(countdown start from 30s)
V—Battery voltage.
I—Battery charging current.
3.3.2.
Solar.
CHARGER CONTROLLER MPPT FOR WIND GENERATOR, WIND TURBINE THALES
V—Solar voltage
I—Solar charging current
3.3.3.
Wind.
      CHARGER CONTROLLER MPPT FOR WIND GENERATOR, WIND TURBINE THALES
**R/min— rotating speed of wind generator. (Normal working state is this display),
Other displays:
W1: Brake—wind generator is manually braked
W2: **S—when battery voltage is greater than “Full”, generator is braking. Exit braking “Time” countdown.
W3: **S—when rotate speed of wind generator is greater than “Rota”, generator is braking. Exit braking “Time” countdown.
W4: **S—when wind generator voltage is greater than “Vmax”, generator is braking. Exit braking “Time” countdown.
W5: **S—when wind generator current is greater than “Amax”, generator is braking. Exit braking “Time” countdown.
W* :Stay—Exit braking “Time” countdown finish, wind generator still stay brake.
“Full”. It should be set in step 5/9 settings "System information".
“Rota”. It should be set in step 2/9 settings "Wind information".
“Vmax”. It should be set in step 6/9 settings "Wind information".
“Amax”. It should be set in step 7/9 settings "Wind information".
“Time”. It should be set in step 8/9 settings "Wind information".
V—wind output voltage.
I—wind charging current.
CHARGER CONTROLLER MPPT FOR WIND GENERATOR, WIND TURBINE THALES
V—wind output power.
I—wind output current.
3.3.4.
Input.
CHARGER CONTROLLER MPPT FOR WIND GENERATOR, WIND TURBINE THALES
In-Power—total input power.
S—solar input power.
W—wind input power.
3.3.5.
Total Generated Energy.
CHARGER CONTROLLER MPPT FOR WIND GENERATOR, WIND TURBINE THALES
Total-Energy—total generated energy.
This value is cumulative. If want to start from 0, set "ENER" in step 2/9 settings "Wind information".
3.3.6.
Temperature Protection.
CHARGER CONTROLLER MPPT FOR WIND GENERATOR, WIND TURBINE THALES
TP—controller device working temperature.
TL—MOS fet temperature.
Normal: Temperature is normal.
Error: Temperature detection module is error.
OTP: Over-temperature protection.
**C: **Celsius degree.
3.3.7.
Error Code
CHARGER CONTROLLER MPPT FOR WIND GENERATOR, WIND TURBINE THALES
B1—battery over-discharge.
B2—battery over-charge.
S1—solar input voltage is high.
S2—solar charging module short-circuit fault.
S3—solar charging module open-circuit fault.
W1—wind generator is manually braked.
W2—battery voltage is greater than “Full”, wind generator brakes.
W3—wind generator rotate speed is greater than “Rota”, generator brakes.
W4—wind generator voltage is higher than “Vmax”, generator brakes.
W5—wind generator current is greater than “Amax”, generator brakes.
W6—brake module short-circuit fault.
W7—wind charging module short-circuit fault.
W8—wind charging module open-circuit fault.
W9—wind input voltage is high.
T1—MOS fet detection module fault.
T2—MOS fet over-temperature protection.
T5—controller device detection module fault.
T6—controller device over-temperature protection.
*0—work normal.
3.3.8.
USB (This is optional function, if not purchase, there is no the following display).
      CHARGER CONTROLLER MPPT FOR WIND GENERATOR, WIND TURBINE THALES
****-**-**—Year-Month-Day.
USB**—USB state
USB interface has the following states:
USBOK—USB well connected
USBNC—USB not connected
USBdErr—USB conversion module damaged or not connected
USBFULL—USB stick is full
**:**:**—Hour: Minute: Second.
3.4.
System Information.
CHARGER CONTROLLER MPPT FOR WIND GENERATOR, WIND TURBINE THALES
3.5.
Wind Information.
CHARGER CONTROLLER MPPT FOR WIND GENERATOR, WIND TURBINE THALES
3.6.
Solar Information.
CHARGER CONTROLLER MPPT FOR WIND GENERATOR, WIND TURBINE THALES
3.7.
Date and Time Setting.
CHARGER CONTROLLER MPPT FOR WIND GENERATOR, WIND TURBINE THALES